Oman Eye Study 2005: validity of screening tests used in the glaucoma survey / Khandekar, R.;Al Raisi, A.

Tác giả : Khandekar, R.;Al Raisi, A.

Năm xuất bản : 2008

Chủ đề : 1. Cross-Sectional Studies. 2. Glaucoma. 3. Health Surveys. 4. Intraocular Pressure. 5. Mass Screening. 6. Optic Disk. 7. Process Assessment Health Care. 8. Sensitivity and Specificity.

Thông tin chi tiết

Tóm tắt :

1360-1364 We carried out a validity assessment study for glaucoma screening procedures used during the survey conducted in Oman in 2005 on 6644 eyes in 3324 people >/= 30 years. Ocular pressure and fundus changes were the screening parameters used: glaucoma was found in 433 eyes. Sensitivity for ocular pressure was 49.7% and specificity 95.6%. For optic disc changes, sensitivity was 48.4% and specificity 97.9%. Combining both through parallel testing, sensitivity improved to 67.3% and specificity to 96.5%. An eye may, thus, be declared as not having glaucoma, but cannot be labelled as having glaucoma, using these parameters